8.1
CVE-2020-3549
- EPSS 0.53%
- Published 21.10.2020 19:15:17
- Last modified 26.11.2024 16:09:02
- Source psirt@cisco.com
- Teams watchlist Login
- Open Login
A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device.
Data is provided by the National Vulnerability Database (NVD)
Cisco ≫ Firepower Threat Defense Version < 6.6.1
Cisco ≫ Secure Firewall Management Center Version < 6.6.1
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.53% | 0.645 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 8.1 | 2.2 | 5.9 |
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
|
nvd@nist.gov | 6.8 | 8.6 | 6.4 |
AV:N/AC:M/Au:N/C:P/I:P/A:P
|
psirt@cisco.com | 8.1 | 2.2 | 5.9 |
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
|
CWE-326 Inadequate Encryption Strength
The product stores or transmits sensitive data using an encryption scheme that is theoretically sound, but is not strong enough for the level of protection required.