5.9

CVE-2020-28395

A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.

Data is provided by the National Vulnerability Database (NVD)
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.17% 0.35
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 5.9 2.2 3.6
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
nvd@nist.gov 4.3 8.6 2.9
AV:N/AC:M/Au:N/C:P/I:N/A:N
CWE-321 Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility that encrypted data may be recovered.

CWE-798 Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.