5.5
CVE-2020-26998
- EPSS 0.1%
- Veröffentlicht 09.02.2021 17:15:13
- Zuletzt bearbeitet 21.11.2024 05:20:39
- Quelle productcert@siemens.com
- CVE-Watchlists
- Unerledigt
A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information. (ZDI-CAN-12040)
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Teamcenter Visualization Version < 13.1.0.2
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.1% | 0.275 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 5.5 | 1.8 | 3.6 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
|
| nvd@nist.gov | 2.1 | 3.9 | 2.9 |
AV:L/AC:L/Au:N/C:P/I:N/A:N
|
CWE-125 Out-of-bounds Read
The product reads data past the end, or before the beginning, of the intended buffer.