6.5

CVE-2020-25180

Rockwell Automation ISaGRAF5 Runtime Use of Hard-coded Cryptographic Key

Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Schneider-electric ≫ Easergy C5 Firmware Version < 1.1.0
   Schneider-electric ≫ Easergy C5 Version -
Schneider-electric ≫ Pacis Gtw Firmware Version 5.1 SwPlatform windows
   Schneider-electric ≫ Pacis Gtw Version -
Schneider-electric ≫ Pacis Gtw Firmware Version 5.2 SwPlatform windows
   Schneider-electric ≫ Pacis Gtw Version -
Schneider-electric ≫ Pacis Gtw Firmware Version 6.1 SwPlatform windows
   Schneider-electric ≫ Pacis Gtw Version -
Schneider-electric ≫ Pacis Gtw Firmware Version 6.3 SwPlatform linux
   Schneider-electric ≫ Pacis Gtw Version -
Schneider-electric ≫ Pacis Gtw Firmware Version 6.3 SwPlatform windows
   Schneider-electric ≫ Pacis Gtw Version -
Schneider-electric ≫ Saitel Dp Firmware Version <= 11.06.21
   Schneider-electric ≫ Saitel Dp Version -
Schneider-electric ≫ Epas Gtw Firmware Version 6.4 SwPlatform linux
   Schneider-electric ≫ Epas Gtw Version -
Schneider-electric ≫ Epas Gtw Firmware Version 6.4 SwPlatform windows
   Schneider-electric ≫ Epas Gtw Version -
Schneider-electric ≫ Saitel Dr Firmware Version <= 11.06.12
   Schneider-electric ≫ Saitel Dr Version -
Schneider-electric ≫ Scd2200 Firmware Version <= 10024
   Schneider-electric ≫ Cp-3 Version -
   Schneider-electric ≫ Mc-31 Version -
Rockwellautomation ≫ Isagraf Free Runtime SwPlatform isagraf6_workbench Version <= 6.6.8
Rockwellautomation ≫ Isagraf Runtime Version >= 5.0 < 6.0
Xylem ≫ Multismart Firmware Version < 3.2.0
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.16% 0.646
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
NIST 6.5 2.8 3.6
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
NIST 4.3 8.6 2.9
AV:N/AC:M/Au:N/C:P/I:N/A:N
DHS.gov 5.3 1.6 3.6
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N
CWE-321 Use of Hard-coded Cryptographic Key

The product uses a hard-coded, unchangeable cryptographic key.

CWE-798 Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.

https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04
Vendor Advisory
https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699
Permissions Required
https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01
Third Party Advisory
US Government Resource
https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf
Third Party Advisory