9.8
CVE-2020-15786
- EPSS 1.48%
- Veröffentlicht 09.09.2020 19:15:19
- Zuletzt bearbeitet 02.06.2026 20:16:24
- Quelle productcert@siemens.com
- CVE-Watchlists
- Unerledigt
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Simatic Hmi Basic Panels 2nd Generation Firmware Version <= 14
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 1.48% | 0.705 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 5 | 10 | 2.9 |
AV:N/AC:L/Au:N/C:P/I:N/A:N
|
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
CWE-307 Improper Restriction of Excessive Authentication Attempts
The product does not implement sufficient measures to prevent multiple failed authentication attempts within a short time frame.
https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf