9.8

CVE-2020-12017

GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.

Data is provided by the National Vulnerability Database (NVD)
GeRt430 Firmware Version < 08a05
   GeRt430 Version-
GeRt431 Firmware Version < 08a05
   GeRt431 Version-
GeRt434 Firmware Version < 08a05
   GeRt434 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.65% 0.685
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd@nist.gov 9 10 8.5
AV:N/AC:L/Au:N/C:P/I:P/A:C
CWE-306 Missing Authentication for Critical Function

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.