9.8

CVE-2020-10611

Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Trianglemicroworks ≫ Scada Data Gateway Version >= 2.41.0213 <= 4.0.122
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 5.23% 0.914
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
NIST 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NIST 7.5 10 6.4
AV:N/AC:L/Au:N/C:P/I:P/A:P
CWE-843 Access of Resource Using Incompatible Type ('Type Confusion')

The product allocates or initializes a resource such as a pointer, object, or variable using one type, but it later accesses that resource using a type that is incompatible with the original type.

https://www.us-cert.gov/ics/advisories/icsa-20-105-03
Third Party Advisory
US Government Resource
https://www.zerodayinitiative.com/advisories/ZDI-20-549/
Third Party Advisory
VDB Entry