7.5

CVE-2020-10267

Exploit
Universal Robots control box CB 3.1 across firmware versions (tested on 1.12.1, 1.12, 1.11 and 1.10) does not encrypt or protect in any way the intellectual property artifacts installed from the UR+ platform of hardware and software components (URCaps). These files (*.urcaps) are stored under '/root/.urcaps' as plain zip files containing all the logic to add functionality to the UR3, UR5 and UR10 robots. This flaw allows attackers with access to the robot or the robot network (while in combination with other flaws) to retrieve and easily exfiltrate all installed intellectual property.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Universal-robotsUr Software Version >= 3.0.14989 <= 3.1.18213
   Universal-robotsUr10 Version-
   Universal-robotsUr3 Version-
   Universal-robotsUr5 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.12% 0.283
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.5 3.9 3.6
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
nvd@nist.gov 5 10 2.9
AV:N/AC:L/Au:N/C:P/I:N/A:N
cve@aliasrobotics.com 7.5 3.9 3.6
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE-311 Missing Encryption of Sensitive Data

The product does not encrypt sensitive or critical information before storage or transmission.

CWE-312 Cleartext Storage of Sensitive Information

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.