7.8

CVE-2019-9534

The Cobham EXPLORER 710, firmware version 1.07, does not validate its firmware image. Development scripts left in the firmware can be used to upload a custom firmware image that the device runs. This could allow an unauthenticated, local attacker to upload their own firmware that could be used to intercept or modify traffic, spoof or intercept GPS traffic, exfiltrate private data, hide a backdoor, or cause a denial-of-service.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
CobhamExplorer 710 Firmware Version1.07
   CobhamExplorer 710 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.06% 0.189
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.8 1.8 5.9
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
nvd@nist.gov 7.2 3.9 10
AV:L/AC:L/Au:N/C:C/I:C/A:C
CWE-494 Download of Code Without Integrity Check

The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.