9.3
CVE-2019-6538
- EPSS 0.22%
- Veröffentlicht 25.03.2019 22:29:00
- Zuletzt bearbeitet 22.05.2025 20:15:20
- Quelle ics-cert@hq.dhs.gov
- CVE-Watchlists
- Unerledigt
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Medtronic ≫ Mycarelink Monitor Firmware Version24950
Medtronic ≫ Mycarelink Monitor Firmware Version24952
Medtronic ≫ Carelink Monitor Firmware Version2490c
Medtronic ≫ Carelink 2090 Firmware Version-
Medtronic ≫ Amplia Crt-d Firmware Version-
Medtronic ≫ Claria Crt-d Firmware Version-
Medtronic ≫ Compia Crt-d Firmware Version-
Medtronic ≫ Concerto Crt-d Firmware Version-
Medtronic ≫ Concerto Ii Crt-d Firmware Version-
Medtronic ≫ Consulta Crt-d Firmware Version-
Medtronic ≫ Evera Icd Firmware Version-
Medtronic ≫ Maximo Ii Crt-d And Lcd Firmware Version-
Medtronic ≫ Mirro Icd Firmware Version-
Medtronic ≫ Nayamed Nd Icd Firmware Version-
Medtronic ≫ Primo Icd Firmware Version-
Medtronic ≫ Protecta Icd And Crt-d Firmware Version-
Medtronic ≫ Secura Icd Firmware Version-
Medtronic ≫ Virtuoso Icd Firmware Version-
Medtronic ≫ Virtuoso Ii Icd Firmware Version-
Medtronic ≫ Visia Af Icd Firmware Version-
Medtronic ≫ Viva Crt-d Firmware Version-
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.22% | 0.445 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 6.5 | 2.8 | 3.6 |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
|
| nvd@nist.gov | 3.3 | 6.5 | 2.9 |
AV:A/AC:L/Au:N/C:N/I:P/A:N
|
| ics-cert@hq.dhs.gov | 9.3 | 2.8 | 5.8 |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H
|
CWE-284 Improper Access Control
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
CWE-306 Missing Authentication for Critical Function
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CWE-862 Missing Authorization
The product does not perform an authorization check when an actor attempts to access a resource or perform an action.