9.3

CVE-2019-6538

Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
MedtronicCarelink Monitor Firmware Version2490c
   MedtronicCarelink Monitor Version-
MedtronicCarelink 2090 Firmware Version-
   MedtronicCarelink 2090 Version-
MedtronicAmplia Crt-d Firmware Version-
   MedtronicAmplia Crt-d Version-
MedtronicClaria Crt-d Firmware Version-
   MedtronicClaria Crt-d Version-
MedtronicCompia Crt-d Firmware Version-
   MedtronicCompia Crt-d Version-
MedtronicConcerto Crt-d Firmware Version-
   MedtronicConcerto Crt-d Version-
MedtronicConsulta Crt-d Firmware Version-
   MedtronicConsulta Crt-d Version-
MedtronicEvera Icd Firmware Version-
   MedtronicEvera Icd Version-
MedtronicMirro Icd Firmware Version-
   MedtronicMirro Icd Version-
MedtronicNayamed Nd Icd Firmware Version-
   MedtronicNayamed Nd Icd Version-
MedtronicPrimo Icd Firmware Version-
   MedtronicPrimo Icd Version-
MedtronicSecura Icd Firmware Version-
   MedtronicSecura Icd Version-
MedtronicVirtuoso Icd Firmware Version-
   MedtronicVirtuoso Icd Version-
MedtronicVisia Af Icd Firmware Version-
   MedtronicVisia Af Icd Version-
MedtronicViva Crt-d Firmware Version-
   MedtronicViva Crt-d Version-
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.84% 0.531
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 6.5 2.8 3.6
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
nvd@nist.gov 3.3 6.5 2.9
AV:A/AC:L/Au:N/C:N/I:P/A:N
ics-cert@hq.dhs.gov 9.3 2.8 5.8
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H
CWE-284 Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

CWE-306 Missing Authentication for Critical Function

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

CWE-862 Missing Authorization

The product does not perform an authorization check when an actor attempts to access a resource or perform an action.

http://www.securityfocus.com/bid/107544
Third Party Advisory
VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01
Third Party Advisory
US Government Resource
Mitigation