10

CVE-2019-3925

Exploit

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.

Data is provided by the National Vulnerability Database (NVD)
CrestronAm-100 Firmware Version1.6.0.2
   CrestronAm-100 Version-
CrestronAm-101 Firmware Version2.7.0.2
   CrestronAm-101 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 30.5% 0.963
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd@nist.gov 10 10 10
AV:N/AC:L/Au:N/C:C/I:C/A:C
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.