9
CVE-2019-1885
- EPSS 1.01%
- Veröffentlicht 21.08.2019 19:15:14
- Zuletzt bearbeitet 21.11.2024 04:37:36
- Quelle psirt@cisco.com
- Teams Watchlist Login
- Unerledigt Login
A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Cisco ≫ Unified Computing System Version4.0(1c)hs3
Cisco ≫ Integrated Management Controller Supervisor Version >= 3.0.0.0 < 3.0\(4k\)
Cisco ≫ Integrated Management Controller Supervisor Version >= 4.0.0.0 < 4.0\(4b\)
Cisco ≫ Integrated Management Controller Supervisor Version >= 4.0.0.0 < 4.0\(2f\)
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Typ | Quelle | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 1.01% | 0.752 |
Quelle | Base Score | Exploit Score | Impact Score | Vector String |
---|---|---|---|---|
nvd@nist.gov | 7.2 | 1.2 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
nvd@nist.gov | 9 | 8 | 10 |
AV:N/AC:L/Au:S/C:C/I:C/A:C
|
psirt@cisco.com | 7.2 | 1.2 | 5.9 |
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.