6.8
CVE-2019-13945
- EPSS 0.15%
- Published 12.12.2019 14:15:15
- Last modified 21.11.2024 04:25:44
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Simatic S7-200 Smart Cpu St20 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu St30 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu St40 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu St60 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu Sr20 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu Sr30 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu Sr40 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu Sr60 Firmware Version <= 2.5.0
Siemens ≫ Simatic S7-200 Smart Cpu Cr40 Firmware Version <= 2.2.2
Siemens ≫ Simatic S7-200 Smart Cpu Cr60 Firmware Version <= 2.2.2
Siemens ≫ Simatic S7-200 Smart Cpu Cr20s Firmware Version <= 2.3.0
Siemens ≫ Simatic S7-200 Smart Cpu Cr30s Firmware Version <= 2.3.0
Siemens ≫ Simatic S7-200 Smart Cpu Cr40s Firmware Version <= 2.3.0
Siemens ≫ Simatic S7-200 Smart Cpu Cr60s Firmware Version <= 2.3.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.15% | 0.361 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 6.8 | 0.9 | 5.9 |
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
nvd@nist.gov | 4.6 | 3.9 | 6.4 |
AV:L/AC:L/Au:N/C:P/I:P/A:P
|
CWE-749 Exposed Dangerous Method or Function
The product provides an Applications Programming Interface (API) or similar interface for interaction with external actors, but the interface includes a dangerous method or function that is not properly restricted.