7.8

CVE-2019-13926

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SiemensScalance S602 Firmware Version >= 3.0 < 4.1
   SiemensScalance S602 Version-
SiemensScalance S612 Firmware Version >= 3.0 < 4.1
   SiemensScalance S612 Version-
SiemensScalance S623 Firmware Version >= 3.0 < 4.1
   SiemensScalance S623 Version-
SiemensScalance S627-2m Firmware Version >= 3.0 < 4.1
   SiemensScalance S627-2m Version-
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.5% 0.711
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.5 3.9 3.6
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
nvd@nist.gov 7.8 10 6.9
AV:N/AC:L/Au:N/C:N/I:N/A:C
CWE-400 Uncontrolled Resource Consumption

The product does not properly control the allocation and maintenance of a limited resource.

https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf
Vendor Advisory
https://www.us-cert.gov/ics/advisories/icsa-20-042-10
Third Party Advisory
US Government Resource