7.1
CVE-2019-11896
- EPSS 0.16%
- Veröffentlicht 29.05.2019 21:29:02
- Zuletzt bearbeitet 21.11.2024 04:21:58
- Quelle psirt@bosch.com
- CVE-Watchlists
- Unerledigt
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Bosch ≫ Smart Home Controller Firmware Version < 9.8.907
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.16% | 0.336 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.1 | 1.2 | 5.9 |
CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 6.8 | 8.6 | 6.4 |
AV:N/AC:M/Au:N/C:P/I:P/A:P
|
| psirt@bosch.com | 5.5 | 2.1 | 3.4 |
CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
|
CWE-269 Improper Privilege Management
The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
CWE-284 Improper Access Control
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.