8.8

CVE-2018-7828

A Cross-Site Request Forgery (CSRF) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera when an authenticated user clicks a specially crafted malicious link while logged into the camera.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Schneider-electric ≫ D6220 Firmware Version >= 2.11
   Schneider-electric ≫ D6220 Version -
Schneider-electric ≫ D6220l Firmware Version >= 2.11
   Schneider-electric ≫ D6220l Version -
Schneider-electric ≫ D6230 Firmware Version >= 2.11
   Schneider-electric ≫ D6230 Version -
Schneider-electric ≫ D6230l Firmware Version >= 2.11
   Schneider-electric ≫ D6230l Version -
Schneider-electric ≫ Imes19-1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1i Version -
Schneider-electric ≫ Imes19-1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1s Version -
Schneider-electric ≫ Imes19-1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1p Version -
Schneider-electric ≫ Ime119-1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1i Version -
Schneider-electric ≫ Ime119-1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1s Version -
Schneider-electric ≫ Ime119-1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1p Version -
Schneider-electric ≫ Ime219-1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1i Version -
Schneider-electric ≫ Ime219-1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1s Version -
Schneider-electric ≫ Ime219-1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1p Version -
Schneider-electric ≫ Ime319-1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1i Version -
Schneider-electric ≫ Ime319-1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1s Version -
Schneider-electric ≫ Ime319-1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1p Version -
Schneider-electric ≫ Ime319-b1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-b1i Version -
Schneider-electric ≫ Ime319-b1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-b1s Version -
Schneider-electric ≫ Ime319-b1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-b1p Version -
Schneider-electric ≫ Ime3122-1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1i Version -
Schneider-electric ≫ Ime3122-b1i Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-b1i Version -
Schneider-electric ≫ Ime3122-1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1s Version -
Schneider-electric ≫ Ime3122-b1s Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-b1s Version -
Schneider-electric ≫ Ime3122-1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1p Version -
Schneider-electric ≫ Ime3122-b1p Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-b1p Version -
Schneider-electric ≫ Imes19-1ei Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1ei Version -
Schneider-electric ≫ Imes19-1es Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1es Version -
Schneider-electric ≫ Imes19-1ep Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1ep Version -
Schneider-electric ≫ Ime119-1ei Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1ei Version -
Schneider-electric ≫ Ime119-1es Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1es Version -
Schneider-electric ≫ Ime119-1ep Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1ep Version -
Schneider-electric ≫ Ime219-1ei Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1ei Version -
Schneider-electric ≫ Ime219-1es Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1es Version -
Schneider-electric ≫ Ime219-1ep Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1ep Version -
Schneider-electric ≫ Ime319-1ei Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1ei Version -
Schneider-electric ≫ Ime319-1es Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1es Version -
Schneider-electric ≫ Ime319-1ep Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1ep Version -
Schneider-electric ≫ Ime3122-1ei Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1ei Version -
Schneider-electric ≫ Ime3122-1es Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1es Version -
Schneider-electric ≫ Ime3122-1ep Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1ep Version -
Schneider-electric ≫ Imes19-1vi Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1vi Version -
Schneider-electric ≫ Imes19-1vs Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1vs Version -
Schneider-electric ≫ Imes19-1vp Firmware Version < 2.2.3.0
   Schneider-electric ≫ Imes19-1vp Version -
Schneider-electric ≫ Ime119-1vi Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1vi Version -
Schneider-electric ≫ Ime119-1vs Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1vs Version -
Schneider-electric ≫ Ime119-1vp Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime119-1vp Version -
Schneider-electric ≫ Ime219-1vi Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1vi Version -
Schneider-electric ≫ Ime219-1vs Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1vs Version -
Schneider-electric ≫ Ime219-1vp Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime219-1vp Version -
Schneider-electric ≫ Ime319-1vi Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1vi Version -
Schneider-electric ≫ Ime319-1vs Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1vs Version -
Schneider-electric ≫ Ime319-1vp Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime319-1vp Version -
Schneider-electric ≫ Ime3122-1vi Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1vi Version -
Schneider-electric ≫ Ime3122-1vs Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1vs Version -
Schneider-electric ≫ Ime3122-1vp Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ime3122-1vp Version -
Schneider-electric ≫ Ixes1 Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ixes1 Version -
Schneider-electric ≫ Ixe11 Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ixe11 Version -
Schneider-electric ≫ Ixe21 Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ixe21 Version -
Schneider-electric ≫ Ixe31 Firmware Version < 2.2.3.0
   Schneider-electric ≫ Ixe31 Version -
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.57% 0.427
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
NIST 8.8 2.8 5.9
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
NIST 6.8 8.6 6.4
AV:N/AC:M/Au:N/C:P/I:P/A:P
CWE-352 Cross-Site Request Forgery (CSRF)

The web application does not, or cannot, sufficiently verify whether a request was intentionally provided by the user who sent the request, which could have originated from an unauthorized actor.

https://www.schneider-electric.com/en/download/document/SEVD-2019-045-03/
Vendor Advisory