7.8

CVE-2018-17909

When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
OmronCx-supervisor Version <= 3.4.1.0
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.63% 0.731
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.8 1.8 5.9
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvd@nist.gov 6.8 8.6 6.4
AV:N/AC:M/Au:N/C:P/I:P/A:P
CWE-416 Use After Free

The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory "belongs" to the code that operates on the new pointer.

http://www.securityfocus.com/bid/105691
Third Party Advisory
VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-18-290-01
Third Party Advisory
US Government Resource