9
CVE-2018-16146
- EPSS 11.08%
- Veröffentlicht 05.09.2018 21:29:02
- Zuletzt bearbeitet 21.11.2024 03:52:09
- Quelle cve@mitre.org
- CVE-Watchlists
- Unerledigt
The web management console of Opsview Monitor 5.4.x before 5.4.2 provides functionality accessible by an authenticated administrator to test notifications that are triggered under certain configurable events. The value parameter is not properly sanitized, leading to arbitrary command injection with the privileges of the nagios user account.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 11.08% | 0.932 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.2 | 1.2 | 5.9 |
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 9 | 8 | 10 |
AV:N/AC:L/Au:S/C:C/I:C/A:C
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.