8.6

CVE-2018-13807

A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versions). The web interface on port 443/tcp could allow an attacker to cause a Denial-of-Service condition by sending specially crafted packets to the web server. The device will automatically reboot, impacting network availability for other devices. An attacker must have network access to port 443/tcp to exploit the vulnerability. Neither valid credentials nor interaction by a legitimate user is required to exploit the vulnerability. There is no confidentiality or integrity impact, only availability is temporarily impacted. This vulnerability could be triggered by publicly available tools.

Data is provided by the National Vulnerability Database (NVD)
SiemensScalance X408 Firmware Version < 4.0.0
   SiemensScalance X408 Version-
SiemensScalance X300 Firmware Version < 4.0.0
   SiemensScalance X300 Version-
SiemensScalance X414 Firmware Version-
   SiemensScalance X414 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 1.15% 0.776
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 8.6 3.9 4
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
nvd@nist.gov 7.8 10 6.9
AV:N/AC:L/Au:N/C:N/I:N/A:C
CWE-20 Improper Input Validation

The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.