CVE-2017-7901
- EPSS 0.08%
- Published 30.06.2017 03:29:00
- Last modified 20.04.2025 01:37:25
- Source ics-cert@hq.dhs.gov
- Teams watchlist Login
- Open Login
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Data is provided by the National Vulnerability Database (NVD)
Rockwellautomation ≫ 1763-l16awa Series A Version <= 16.000
Rockwellautomation ≫ 1763-l16awa Series B Version <= 16.000
Rockwellautomation ≫ 1763-l16bbb Series A Version <= 16.000
Rockwellautomation ≫ 1763-l16bbb Series B Version <= 16.000
Rockwellautomation ≫ 1763-l16bwa Series A Version <= 16.000
Rockwellautomation ≫ 1763-l16bwa Series B Version <= 16.000
Rockwellautomation ≫ 1763-l16dwd Series A Version <= 16.000
Rockwellautomation ≫ 1763-l16dwd Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32awa Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32awa Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32awaa Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32awaa Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32bwa Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32bwa Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32bwaa Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32bwaa Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32bxb Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32bxb Series B Version <= 16.000
Rockwellautomation ≫ 1766-l32bxba Series A Version <= 16.000
Rockwellautomation ≫ 1766-l32bxba Series B Version <= 16.000
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.08% | 0.198 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 8.6 | 3.9 | 4.7 |
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
|
nvd@nist.gov | 9 | 10 | 8.5 |
AV:N/AC:L/Au:N/C:P/I:P/A:C
|
CWE-330 Use of Insufficiently Random Values
The product uses insufficiently random numbers or values in a security context that depends on unpredictable numbers.
CWE-343 Predictable Value Range from Previous Values
The product's random number generator produces a series of values which, when observed, can be used to infer a relatively small range of possibilities for the next value that could be generated.