4.9

CVE-2017-6867

A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.

Data is provided by the National Vulnerability Database (NVD)
SiemensSimatic Wincc Version7.3
SiemensSimatic Wincc Version7.4
SiemensSimatic Wincc Runtime Version13 Updatesp1 SwEditionprofessional
SiemensSimatic Wincc Runtime Version14 SwEditionprofessional
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.61% 0.673
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 4.9 1.2 3.6
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
nvd@nist.gov 4 8 2.9
AV:N/AC:L/Au:S/C:N/I:N/A:P
CWE-20 Improper Input Validation

The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.

CWE-787 Out-of-bounds Write

The product writes data past the end, or before the beginning, of the intended buffer.