10
CVE-2017-18044
- EPSS 82.65%
- Veröffentlicht 19.01.2018 17:29:00
- Zuletzt bearbeitet 21.11.2024 03:19:14
- Quelle cve@mitre.org
- CVE-Watchlists
- Unerledigt
A Command Injection issue was discovered in ContentStore/Base/CVDataPipe.dll in Commvault before v11 SP6. A certain message parsing function inside the Commvault service does not properly validate the input of an incoming string before passing it to CreateProcess. As a result, a specially crafted message can inject commands that will be executed on the target operating system. Exploitation of this vulnerability does not require authentication and can lead to SYSTEM level privilege on any system running the cvd daemon. This is a different vulnerability than CVE-2017-3195.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 82.65% | 0.992 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 10 | 10 | 10 |
AV:N/AC:L/Au:N/C:C/I:C/A:C
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.