7.1

CVE-2017-18019

In K7 Total Security before 15.1.0.305, user-controlled input to the K7Sentry device is not sufficiently sanitized: the user-controlled input can be used to compare an arbitrary memory address with a fixed value, which in turn can be used to read the contents of arbitrary memory. Similarly, the product crashes upon a \\.\K7Sentry DeviceIoControl call with an invalid kernel pointer.

Data is provided by the National Vulnerability Database (NVD)
K7computingTotal Security Version < 15.1.0.305
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 1.43% 0.788
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 7.1 1.8 5.2
CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
nvd@nist.gov 3.6 3.9 4.9
AV:L/AC:L/Au:N/C:P/I:N/A:P
CWE-20 Improper Input Validation

The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.