7.8

CVE-2017-16745

A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An access of resource using incompatible type ('type confusion') vulnerability may allow an attacker to execute remote code when processing specially crafted .dpb files.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.09% 0.61
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.8 1.8 5.9
CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
nvd@nist.gov 6.8 8.6 6.4
AV:N/AC:M/Au:N/C:P/I:P/A:P
CWE-704 Incorrect Type Conversion or Cast

The product does not correctly convert an object, resource, or structure from one type to a different type.

CWE-843 Access of Resource Using Incompatible Type ('Type Confusion')

The product allocates or initializes a resource such as a pointer, object, or variable using one type, but it later accesses that resource using a type that is incompatible with the original type.

http://www.securityfocus.com/bid/102426
Third Party Advisory
VDB Entry
https://ics-cert.us-cert.gov/advisories/ICSA-18-004-01
Third Party Advisory