7.5
CVE-2017-14022
- EPSS 0.04%
- Published 23.12.2017 00:29:13
- Last modified 20.04.2025 01:37:25
- Source ics-cert@hq.dhs.gov
- Teams watchlist Login
- Open Login
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.
Data is provided by the National Vulnerability Database (NVD)
Rockwellautomation ≫ Factorytalk Alarms And Events Version <= 2.90
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.04% | 0.066 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 7.5 | 3.9 | 3.6 |
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
|
nvd@nist.gov | 5 | 10 | 2.9 |
AV:N/AC:L/Au:N/C:N/I:N/A:P
|
CWE-20 Improper Input Validation
The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.