4.3

CVE-2016-7090

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.

Data is provided by the National Vulnerability Database (NVD)
SiemensScalance M-800 Firmware Version <= 4.01
   SiemensScalance M-800 Version-
SiemensScalance S615 Firmware Version <= 4.01
   SiemensScalance S615 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.67% 0.705
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 4 2.2 1.4
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N
nvd@nist.gov 4.3 8.6 2.9
AV:N/AC:M/Au:N/C:P/I:N/A:N
CWE-200 Exposure of Sensitive Information to an Unauthorized Actor

The product exposes sensitive information to an actor that is not explicitly authorized to have access to that information.