7.3

CVE-2015-1014

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Data is provided by the National Vulnerability Database (NVD)
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.06% 0.146
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 7.3 1.3 5.9
CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
nvd@nist.gov 4.4 3.4 6.4
AV:L/AC:M/Au:N/C:P/I:P/A:P
CWE-427 Uncontrolled Search Path Element

The product uses a fixed or controlled search path to find resources, but one or more locations in that path can be under the control of unintended actors.