4
CVE-2013-0671
- EPSS 0.18%
- Published 21.03.2013 14:55:01
- Last modified 11.04.2025 00:51:21
- Source ics-cert@hq.dhs.gov
- Teams watchlist Login
- Open Login
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Wincc Tia Portal Version11.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.18% | 0.366 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 4 | 8 | 2.9 |
AV:N/AC:L/Au:S/C:P/I:N/A:N
|
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.