6.1

CVE-2012-1800

Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SiemensScalance S Firmware Version <= 2.3.0
SiemensScalance S Firmware Version2.1.0
SiemensScalance S Firmware Version2.2.0
SiemensScalance S602 Versionv2
SiemensScalance S612 Versionv2
SiemensScalance S613 Versionv2
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.25% 0.48
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 6.1 6.5 6.9
AV:A/AC:L/Au:N/C:N/I:N/A:C
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.