10

CVE-2012-0245

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet.

Data is provided by the National Vulnerability Database (NVD)
AbbInterlink Module Version-
AbbIrc5 Opc Server Version-
AbbPc Sdk Version-
AbbPickmaster 3 Version-
AbbPickmaster 5 Version-
AbbRobot Communications Runtime Version <= 5.14.01
AbbRobotstudio Version-
AbbRobview 5 Version-
AbbWebware Sdk Version-
AbbWebware Server Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 27.46% 0.959
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 10 10 10
AV:N/AC:L/Au:N/C:C/I:C/A:C
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.