7.8
CVE-2010-2772
- EPSS 0.31%
- Veröffentlicht 22.07.2010 05:43:58
- Zuletzt bearbeitet 11.04.2025 00:51:21
- Quelle cve@mitre.org
- CVE-Watchlists
- Unerledigt
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Simatic Wincc Version6.2
Siemens ≫ Simatic Wincc Version7.0
Siemens ≫ Simatic Pcs 7 Version6.0
Siemens ≫ Simatic Pcs 7 Version6.1
Siemens ≫ Simatic Pcs 7 Version7.0 Update-
Siemens ≫ Simatic Pcs 7 Version7.0 Updatesp1
Siemens ≫ Simatic Pcs 7 Version7.1
Siemens ≫ Simatic Pcs 7 Version7.1 Updatesp1
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.31% | 0.513 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.8 | 1.8 | 5.9 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 6.9 | 3.4 | 10 |
AV:L/AC:M/Au:N/C:C/I:C/A:C
|
CWE-798 Use of Hard-coded Credentials
The product contains hard-coded credentials, such as a password or cryptographic key.