Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Automated Solutions ≫ Modbus Slave Activex Control Version <= 1.4
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 4.73% | 0.907 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.5 | 10 | 6.4 |
AV:N/AC:L/Au:N/C:P/I:P/A:P
|
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer
The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
http://dvlabs.tippingpoint.com/advisory/TPTI-07-15
http://osvdb.org/38259
http://www.automatedsolutions.com/pub/asmbslv/ReadMe.htm
http://www.kb.cert.org/vuls/id/981849
http://www.nessus.org/plugins/index.php?view=single&id=26066
http://www.securityfocus.com/archive/1/479967/100/0/threaded
http://www.securityfocus.com/bid/25713
http://www.securitytracker.com/id?1018707
https://exchange.xforce.ibmcloud.com/vulnerabilities/36677