CVE-2025-58320
- EPSS 0.05%
- Veröffentlicht 11.09.2025 08:51:49
- Zuletzt bearbeitet 26.09.2025 14:43:41
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
- EPSS 0.11%
- Veröffentlicht 11.09.2025 08:50:12
- Zuletzt bearbeitet 26.09.2025 14:43:15
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
CVE-2022-2660
- EPSS 0.23%
- Veröffentlicht 13.12.2022 22:15:09
- Zuletzt bearbeitet 21.11.2024 07:01:27
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
CVE-2022-2969
- EPSS 0.2%
- Veröffentlicht 01.12.2022 18:15:10
- Zuletzt bearbeitet 21.11.2024 07:02:00
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly ne...
CVE-2021-38403
- EPSS 0.29%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:00
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter supplier of the API maintenance, which may allow an attacker to remot...
CVE-2021-38407
- EPSS 0.29%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:01
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter name of the API devices, which may allow an attacker to remotely exec...
CVE-2021-38411
- EPSS 0.2%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:01
Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated attacker can inject arbitrary JavaScript code into the parameter deviceName of the API modbusWriter-Reader, which may allow an attacke...
CVE-2021-38416
- EPSS 0.05%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:02
Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed.
CVE-2021-38418
- EPSS 0.07%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:02
Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be positioned between the traffic and perform a machine-in-the-middle attack to access information without authorization.
CVE-2021-38420
- EPSS 0.03%
- Veröffentlicht 03.11.2021 20:15:08
- Zuletzt bearbeitet 21.11.2024 06:17:03
Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged user accounts, which may allow an attacker to modify the installation directory and upload malicious files.