7 Schwachstellen gefunden.

Hinweis: Diese Liste kann unvollständig sein. Daten werden ohne Gewähr im Ursprungsformat bereitgestellt.
  • EPSS 0.51%
  • Veröffentlicht 10.08.2022 12:15:12
  • Zuletzt bearbeitet 21.11.2024 07:12:47

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

  • EPSS 1.26%
  • Veröffentlicht 10.08.2022 12:15:12
  • Zuletzt bearbeitet 21.11.2024 07:12:47

Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.

  • EPSS 0.37%
  • Veröffentlicht 10.08.2022 12:15:12
  • Zuletzt bearbeitet 21.11.2024 07:12:47

Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.

  • EPSS 1.08%
  • Veröffentlicht 13.07.2021 11:15:08
  • Zuletzt bearbeitet 10.12.2024 14:15:19

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.

  • EPSS 0.91%
  • Veröffentlicht 15.03.2021 17:15:21
  • Zuletzt bearbeitet 21.11.2024 05:55:15

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), ...

  • EPSS 0.44%
  • Veröffentlicht 11.05.2017 10:29:00
  • Zuletzt bearbeitet 20.04.2025 01:37:25

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affec...

  • EPSS 2.34%
  • Veröffentlicht 11.05.2017 01:29:05
  • Zuletzt bearbeitet 20.04.2025 01:37:25

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.