CVE-2023-20558
- EPSS 0.26%
- Published 02.04.2023 21:15:08
- Last modified 20.02.2025 20:15:44
Insufficient control flow management in AmdCpmOemSmm may allow a privileged attacker to tamper with the SMM handler potentially leading to an escalation of privileges.
CVE-2023-20559
- EPSS 0.26%
- Published 02.04.2023 21:15:08
- Last modified 25.02.2025 17:15:11
Insufficient control flow management in AmdCpmGpioInitSmm may allow a privileged attacker to tamper with the SMM handler potentially leading to escalation of privileges.
CVE-2022-23824
- EPSS 0.03%
- Published 09.11.2022 21:15:13
- Last modified 21.11.2024 06:49:19
IBPB may not prevent return branch predictions from being specified by pre-IBPB branch targets leading to a potential information disclosure.
CVE-2021-26384
- EPSS 0.14%
- Published 14.07.2022 20:15:08
- Last modified 21.11.2024 05:56:15
A malformed SMI (System Management Interface) command may allow an attacker to establish a corrupted SMI Trigger Info data structure, potentially leading to out-of-bounds memory reads and writes when triggering an SMI resulting in a potential loss of...
CVE-2022-23825
- EPSS 0.19%
- Published 14.07.2022 20:15:08
- Last modified 21.11.2024 06:49:19
Aliases in the branch predictor may cause some AMD processors to predict the wrong branch type potentially leading to information disclosure.
CVE-2022-29900
- EPSS 1.41%
- Published 12.07.2022 19:15:08
- Last modified 21.11.2024 06:59:55
Mis-trained branch predictions for return instructions may allow arbitrary speculative code execution under certain microarchitecture-dependent conditions.
CVE-2022-23823
- EPSS 0.5%
- Published 15.06.2022 20:15:17
- Last modified 21.11.2024 06:49:19
A potential vulnerability in some AMD processors using frequency scaling may allow an authenticated attacker to execute a timing attack to potentially enable information disclosure.
CVE-2021-26373
- EPSS 0.12%
- Published 11.05.2022 17:15:08
- Last modified 21.11.2024 05:56:14
Insufficient bound checks in the System Management Unit (SMU) may result in a system voltage malfunction that could result in denial of resources and/or possibly denial of service.
CVE-2021-26388
- EPSS 0.12%
- Published 11.05.2022 17:15:08
- Last modified 21.11.2024 05:56:16
Improper validation of the BIOS directory may allow for searches to read beyond the directory table copy in RAM, exposing out of bounds memory contents, resulting in a potential denial of service.
CVE-2021-26352
- EPSS 0.13%
- Published 10.05.2022 19:15:08
- Last modified 21.11.2024 05:56:11
Insufficient bound checks in System Management Unit (SMU) PCIe Hot Plug table may result in access/updates from/to invalid address space that could result in denial of service.