5.4
CVE-2026-21639
- EPSS 0.04%
- Veröffentlicht 08.01.2026 16:14:22
- Zuletzt bearbeitet 14.01.2026 21:06:35
- Quelle support@hackerone.com
- CVE-Watchlists
- Unerledigt
A malicious actor in Wi-Fi range of the affected product could leverage a vulnerability in the airMAX Wireless Protocol to achieve a remote code execution (RCE) within the affected product. Affected Products: airMAX AC (Version 8.7.20 and earlier) airMAX M (Version 6.3.22 and earlier) airFiber AF60-XG (Version 1.2.2 and earlier) airFiber AF60 (Version 2.6.7 and earlier) Mitigation: Update your airMAX AC to Version 8.7.21 or later. Update your airMAX M to Version 6.3.24 or later. Update your airFiber AF60-XG to Version 1.2.3 or later. Update your airFiber AF60 to Version 2.6.8 or later.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Ui ≫ Airmax Ac Firmware Version < 8.7.21
Ui ≫ Airmax M Firmware Version < 6.3.24
Ui ≫ Airfiber Af60-xg Firmware Version < 1.2.3
Ui ≫ Airfiber Af60 Firmware Version < 2.6.8
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.04% | 0.132 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | 5.4 | 2.8 | 2.5 |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
|
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.