9.1

CVE-2023-3267

When adding a remote backup location, an authenticated user can pass arbitrary OS commands through the username field. The username is passed without sanitization into CMD running as NT/Authority System. An authenticated attacker can leverage this vulnerability to execute arbitrary code with system-level access to the CyberPower PowerPanel Enterprise server.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
CyberpowerPowerpanel Server SwEditionenterprise Version < 2.6.9
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.23% 0.46
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 8.8 2.8 5.9
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
trellixpsirt@trellix.com 9.1 2.3 6
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.