9.8
CVE-2023-2071
- EPSS 0.67%
- Veröffentlicht 12.09.2023 14:15:09
- Zuletzt bearbeitet 21.11.2024 07:57:52
- Quelle PSIRT@rockwellautomation.com
- Teams Watchlist Login
- Unerledigt Login
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets. The device has the functionality, through a CIP class, to execute exported functions from libraries. There is a routine that restricts it to execute specific functions from two dynamic link library files. By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Rockwellautomation ≫ Factorytalk View SwEditionmachine Version <= 13.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Typ | Quelle | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.67% | 0.703 |
Quelle | Base Score | Exploit Score | Impact Score | Vector String |
---|---|---|---|---|
nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
PSIRT@rockwellautomation.com | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
CWE-20 Improper Input Validation
The product receives input or data, but it does not validate or incorrectly validates that the input has the properties that are required to process the data safely and correctly.
CWE-434 Unrestricted Upload of File with Dangerous Type
The product allows the upload or transfer of dangerous file types that are automatically processed within its environment.