5.9

CVE-2022-43704

Exploit
The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device's physical environment.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SinilinkXy-wft1 Firmware Version1.3.6
   SinilinkXy-wft1 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.63% 0.816
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 5.9 2.2 3.6
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
134c704f-9b21-4f2e-91b3-4a467353bcc0 5.9 2.2 3.6
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
CWE-294 Authentication Bypass by Capture-replay

A capture-replay flaw exists when the design of the product makes it possible for a malicious user to sniff network traffic and bypass authentication by replaying it to the server in question to the same effect as the original message (or with minor changes).