In ProLink PRC2402M V1.0.18 and older, the set_sys_cmd function in the adm.cgi binary, accessible with a page parameter value of sysCMD contains a trivial command injection where the value of the command parameter is passed directly to system.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Prolink ≫ Prc2402m Firmware Version <= 1.0.18
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 11.79% | 0.93 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 7.5 | 10 | 6.4 |
AV:N/AC:L/Au:N/C:P/I:P/A:P
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')