7.1

CVE-2021-23842

Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
BoschAmc2 Firmware Version-
   BoschAmc2 Version-
BoschAccess Professional Edition Version <= 3.8.0
BoschBuilding Integration System Version < 4.9.1
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.03% 0.044
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 7.1 1.8 5.2
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
nvd@nist.gov 3.6 3.9 4.9
AV:L/AC:L/Au:N/C:P/I:P/A:N
psirt@bosch.com 5.7 2.1 3.6
CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
CWE-321 Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility that encrypted data may be recovered.

CWE-798 Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.