9
CVE-2020-5756
- EPSS 1.76%
- Veröffentlicht 17.07.2020 21:15:13
- Zuletzt bearbeitet 21.11.2024 05:34:32
- Quelle vulnreport@tenable.com
- CVE-Watchlists
- Unerledigt
Grandstream GWN7000 firmware version 1.0.9.4 and below allows authenticated remote users to modify the system's crontab via undocumented API. An attacker can use this functionality to execute arbitrary OS commands on the router.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Grandstream ≫ Gwn7000 Firmware Version <= 1.0.9.4
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 1.76% | 0.82 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 8.8 | 2.8 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 9 | 8 | 10 |
AV:N/AC:L/Au:S/C:C/I:C/A:C
|
CWE-489 Active Debug Code
The product is deployed to unauthorized actors with debugging code still enabled or active, which can create unintended entry points or expose sensitive information.
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.