A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Data is provided by the National Vulnerability Database (NVD)
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.42% 0.591
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd@nist.gov 5 10 2.9
AV:N/AC:L/Au:N/C:P/I:N/A:N
CWE-287 Improper Authentication

When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

CWE-305 Authentication Bypass by Primary Weakness